    1. ACCURA Drop-on-Demand-Technology

      ACCURA Drop-on-Demand-Technology

      Sustainable and Precise: Energy-Efficient Coating with ACCURA Drop-on-Demand Technology In an era where sustainability and energy efficiency are key topics, IPR Robotics introduces a groundbreaking solution for precise and environmentally friendly coating with its ACCURA product family. Utilizing innovative Drop-on-Demand (DoD) technology, ACCURA revolutionizes the coating process, offering numerous benefits across various industries. PRECISION AND SUSTAINABILITY IN PERFECTION The Drop-on-Demand technology enables highly precise, contactless coating, where material droplets are only released when needed. Thanks to the ACCURA process, this results in edge-sharp coating without overspray. With a droplet output of up to 2,000 drops per second and the ability to intelligently overlay droplets with robots or gantries, sharp-edged lines are created that precisely cover the desired area. This process ensures not only optimal layer thickness but also high process safety and efficiency. VERSATILE APPLICATIONS OF ACCURA TECHNOLOGY The ACCURA technology is applied in a wide range of industries, offering tailored solutions for diverse coating requirements: Functional Coatings: Enhancing functionality and corrosion protection on battery modules and cells. Electronics: Precise application of solder pastes and protective coatings on circuit boards. Medical Devices: Biocompatible coatings that must be applied accurately and safely. Automotive Industry: Durable coatings for parts that must withstand high stresses and environmental conditions.

    2. Active network components for Ethernet applications

      Active network components for Ethernet applications

      Connect, distribute, network: groundbreaking industry automation cannot be achieved without intelligent networking of production facilities. The digitalisation of production processes requires that the individual components of a production environment communicate with one another and with information systems. A reliable data exchange is essential for this. LAPP supports the transmission of simple control signals as well as protocol-based fieldbus or Ethernet signals with network and distribution components for sensor actuator, fieldbus and Ethernet applications. After all, the future of industry starts with choosing the right components.

    3. ACURIA

      ACURIA

      ACURIA is the most precise machine light we have ever built as a machine light professional. With the most powerful, efficient lighting technology. With the best tightness. The safest protection against high temperatures. The best cable protection and the easiest installation. The simplest control and the most seamless integration. More precisely thought, more precisely shaped, more precisely built. A perfect combination of Waldmann know-how for industrial lighting and application-oriented design language by renowned product designer Dominic Schindler.

    4. AD-FM 600 GT

      AD-FM 600 GT

      The AD-FM 300 GT (1-channel) and AD-FM 600 GT (2-channel) are freely programmable frequency/analog measuring transducers with integrated display unit. Due to its multifunctional processing of the input frequency and the up to 2 analog outputs (current/voltage) per channel or the evaluable digital outputs, the device is optimally suited for the display of instantaneous flow rates with simultaneous evaluable counting pulse output for water meters with main and sub meters. Especially for large water meters with bypass, a scaled summation is integrated in the AD-FM 600 GT. Both the instantaneous flows and the counted quantities are output. A low level suppression is shiftable. Application The main area of application is the through-flow measuring at water meters. Further applications are the measuring of rotation speed or energy consumption. Specific characteristics - 1 (AD-FM 300 GT) or 2 (AD-FM 600 GT) channels in just one housing - Inputs: NAMUR, contact, open collector, 3-conductor Opto, 24V activ - Analog outputs: each channel 1 current and 1 voltage (synchronous) - Digital outputs: relay respectively optocouple (puls function or limit contact) - Scaled summation and shiftable low level suppression - Programming directly on the device or free programming software - DIN rail mounting

    5. AD-LU 20 GT

      AD-LU 20 GT

      The digital power and energy meter AD-LU 20 GT measures all standard values of the three-phase system (active-, reactive-, apparent-power, voltage, currents, harmonics, power factor etc.) and provides this via an Ethernet interface. The measured values can be read out via Modbus-TCP protocol. In addition, these measured values are displayed on an integrated small WEB server. The device can also be parameterized via this WEB server. The AD-LU 20 GT is also equipped with an RS485 interface. This RS485 interface with Modbus-RTU protocol is mainly suitable for connecting an external display (AD-MM 400), but can also be used to read data or parameterize. The current is fed via the front-mounted through-current converters, which can measure up to 20 A directly. However, additional current transformers for larger currents can also be connected at any time. It is possible to measure symmetrical or unbalanced 4-wire networks and symmetrically loaded 3-wire networks. Due to the integrated, efficient wide-range power supply, the device operates in a large supply voltage range and does not heat up very much.

    6. AD-LU 40 GT-PN

      AD-LU 40 GT-PN

      The digital power converter AD-LU 40 GT measures all values of the three-phase power grid such as current, voltage, energy, active, reactive, apparent power and frequency and makes this data available via a fieldbus. The device is therefore ideally suited for integration into energy management systems. The ProfiNet variant contains a 2-port switch for direct forwarding to the next device. 3- or 4-wire networks can be measured. 4-wire networks may have balanced or unbalanced load. 3-wire networks must have balanced load. The AD-LU 40 GT is powered by its measuring voltage L1. However, a variant with separate supply terminals and wide-range power supply is also available (AD-LU 40-S GT). The current measurement takes place via the throughput converters attached to the front. For the measurement of higher voltages or currents, external converters can be connected at any time. LEDs on the front panel signal the operating state and the data traffic. The compact design and the high performance combined with low energy consumption allow it to be used in almost any application. In addition, the device has a front-sided RS485 interface to which, for example, the TFT display AD-MM 400 can be connected. Thus, without any great effort, all measured values can be displayed. Application Measurement and monitoring of all electrical characteristics in electrical systems. Detection of load profiles for energy management systems, e.g. ISO 50001. Recording the energy consumption of individual consumers. Monitoring of voltage quality variables, e.g. Harmonics. Attention: This is a Class A product according to EN 55011. Additional EMC actions may be necessary when used in small businesses or in residential areas. Specific characteristics - Fieldbus interface for PROFINET or PROFIBUS - RS485 interface for connecting a TFT display

    7. AD-LU 410 GT

      AD-LU 410 GT

      Especially in power plant operations but also in many other switchgear areas, active power for the optimization and control of processes must be continuously measured. The power converter AD-LU 410 GT is always adapted to the individual case by means of plant-specific adaptations. Due to the fully analog design, fast power measurements are possible, e.g. the detection of short-time load changes. The nominal voltage, the power to be measured and the desired output signal are required by the customer. The exact power values are available as standard signal for further processing.

    8. AD-LU 650 GT

      AD-LU 650 GT

      The AD-LU 650 GT is a digital measuring transducers for the acquisition of all measured variables in the three-phase network. In addition to the fundamental oscillations, the harmonics up to the 32nd harmonic are also measured for currents and voltages. In addition to the three phase currents, the current in the neutral conductor can also be measured. Any measured variable can be assigned to each analog output. Each digital output can be assigned its own function such as limit value monitoring or pulse output for an energy meter. All measured data can be read out via the Modbus-RTU interface. With an optional display device such as the AD-MM 400 FE or the AD-MM 500 FE, the data can be displayed and the device can be configured if necessary.

    9. AD-PVO 6100 GT

      AD-PVO 6100 GT

      Photovoltaic surplus controller with three load relays, analog and digital outputs, temperature measurement, Ethernet, USB, RS485, WiFi and display. The AD-PVO 6100 GT photovoltaic optimizer monitors the feed-in of any surplus PV energy at a building's main connection. If the feed-in power exceeds a limit value parameterized by the operator, up to three independent load relays can be activated. These three load relays can be individually parameterized and can therefore switch loads either in phases or in steps to the total power. These switching relays can now be used to control electrical loads (e.g. electric heating element in the domestic hot water tank of the heating system, air conditioning unit or heat pump). With the AD-PVO 6100 GT, the energy is converted on site and not fed back into the public low-voltage grid.

    10. AD-STVEX 710 GVD

      AD-STVEX 710 GVD

      The AD-STVEX 710 GVD supply isolating amplifier is used for the intrinsically safe supply of a transmitter installed in the hazardous area. The supply isolation amplifier itself is installed as associated electrical equipment in the non-hazardous area, i.e. the safe area. The signal is galvanically isolated and transmitted to the non-hazardous area. The passive input also allows active signals from the hazardous area. The active current output, the current sink output and the voltage output facilitate the adaptation to the following signal input. The device can be operated at 24 V DC or 230 V AC. Application Supply of a transmitter in the hazardous area and galvanic isolation of the signal. Specific characteristics - Supply of a transmitter up to zone 0 (gas) or 20 (dust) - Active current output, current sink output and voltage output - Open-circuit detection according to Namur recommendation NE43 - Further parameters configurable via configuration software AD-Studio - Detachable, coded connection terminals - Zero and full scale adjustment possible via front panel keys